LPG compatibility - Resistance to Corrosion - Resistance
to dry heat - Ozone Ageing - Surface Leakage Experiment
Injector
Pressure of Design
:4,5 Bar
Temperature of Heat
:120 °C
Experiment of overpressure
:10 Bar
Experiment of surface leakage
:6,75 Bar
Experiment of socket leakage
:4,5 Bar
LPG compatibility - Resistance to Corrosion - Resistance
to dry heat - Ozone Ageing - Surface Leakage Experiment
Filter
Pressure of Design
:4,5 Bar
Temperature of Heat
:120 °C
Experiment of overpressure
:10 Bar
Experiment of surface leakage
:6,75 Bar
Experiment of socket leakage
:4,5 Bar
LPG compatibility - Resistance to Corrosion - Resistance
to dry heat - Ozone Ageing - Surface Leakage Experiment
Electronic Control Unit
Test of electromagnetic compatibility (EMC)
Guarded with IP 64 waterproof. There would not be any data
loss even if the accumulator is unstitched. Motor is programming
itself while it is working. Petrol shares all the signals with
its ECU. It controls injection time of LPG injections at the
sensibility of microsecond.
Gas Valve
Pressure of Design
:30 Bar
Temperature of Heat
:120 °C
Experiment of overpressure
:67,5 Bar
Experiment of surface leakage
:45 Bar
Experiment of socket leakage
:30 Bar
LPG compatibility - Resistance to Corrosion - Resistance
to dry heat - Ozone Ageing - Surface Leakage Experiment